Feasibility, Safety, and Efficacy of the Atrial Flow Regulator in Pediatric Patients: A Single-Center Experience

Biagio Castaldi, Elena Cuppini, Domenico Sirico, Irene Cattapan, Jennifer Fumanelli, Alice Pozza, Giovanni Di Salvo
University Hospital of Padova.
Italy

Journal of the Society for Cardiovascular Angiography and Interventions
J Soc Cardiovasc Angiogr Interv 2023; 2(6Part B):
DOI: 10.1016/j.jscai.2023.101209

Abstract
Background: The Atrial Flow Regulator (AFR; Occlutech) can be used to create interatrial communication with a predetermined diameter in various pathophysiological settings. In the pediatric population, the experience is limited to a few case reports. We aim to report the initial single-center experience of AFR implantation in children with congenital and acquired heart disease.
Methods: From December 2021 to June 2023, we enrolled 10 patients (aged 6 months-16 years). Indications to treatment were: left ventricular systolic dysfunction (n = 6), restrictive cardiomyopathy with pulmonary hypertension (n = 2), postoperative right ventricle dysfunction after surgical repair of a native Tetralogy of Fallot in a 12-year-old child (n = 1), and failure Fontan (n = 1). AFR implantation was successfully performed in all patients. Transseptal puncture was needed in 8 cases; in the other 2 cases, preexisting patent foramen ovale and fenestrated atrial septal defect were used. Balloon predilation was performed in 9 cases. An 8 mm device was implanted in all cases. The mean time of the procedure was 50 minutes, the median fluoroscopy time was 17 minutes, and median radiation exposure dose was 2.3 Gy × cm2.
Results: No complications were reported during the procedure. Three patients died during the follow-up: 1 due to sepsis (16 days after the procedure), 1 due to disease progression (8 months after), and 1 due to failure of ECMO decannulation 7 days after the atrial venting. In the remaining patients, a reduction of LA dilation, postcapillary pulmonary hypertension, and heart failure symptoms were observed.
Conclusions: AFR is safe and feasible in children and critical settings, allowing right/left cavities unloading and improvement of hemodynamics and symptoms.

Category
Class II. Pulmonary Hypertension Associated with Left Ventricular Systolic or Diastolic Dysfunction
Surgical and Catheter-mediated Interventions for Pulmonary Vascular Disease

Age Focus: Pediatric Pulmonary Vascular Disease

Fresh or Filed Publication: Filed (PHiled). Greater than 1-2 years since publication

Article Access
Free PDF File or Full Text Article Available Through PubMed or DOI: Yes